日韩精品成人a在线观看-日韩精品成人免费观看-日韩精品成人在线-日韩精品大片-日韩精品第三页-日韩精品福利

Small meteorological station
Small meteorological station

Product Center

Contact Us

Shandong Wanxiang Environmental Technology Co., Ltd

contacts :Manager LIU

Telephone :13276362033

QQ:1294284350

Company Address:The second floor of the first accelerator of the Optoelectronic Industry Park, No. 155 Incubation Second Lane, High tech Zone, Weifang City, Shandong Province

Soil moisture monitoring station

Soil moisture monitoring station

update time :2025-02-05

Model:WX-GS3

Product Price: Electronic Negotiation

Product brand: Wanxiang Environment

Soil moisture monitoring station, also known as tubular soil moisture monitoring device, is a monitoring instrument used to monitor soil temperature and humidity, soil moisture, soil conductivity and other parameters. It can be widely used in the agricultural field
product details

Soil moisture monitoring station, also known as tubular soil moisture monitoring device, is a monitoring instrument used to monitor soil temperature and humidity, soil moisture, soil conductivity and other parameters. It can be widely used in the agricultural field

1. Product Introduction

The tubular soil sensor is a sensor used to monitor soil profile temperature, soil profile moisture, and soil profile conductivity. It integrates soil temperature, moisture, and conductivity and can be widely used in smart greenhouses, smart orchards, smart irrigation and other agricultural engineering fields.

2. Product Parameters

Sensor start time: 60S

Sensor power supply voltage: DC12V

Sensor supply current: 22mA

Sensor power consumption: 0.26W

Communication method: 485 Modbus RTU protocol

Measurement parameters: 3 layers can be measured simultaneously (the number of layers can be customized if the number is less than 10 layers)

Measurement principle: A mathematical model is established by measuring the soil dielectric constant, and a spiral measuring electrode is designed to measure the soil volume moisture content data.

parameterMeasuring rangeAccuracyResolutionunit

Soil temperature-30~70℃±0.3 (-10~70℃)0.01℃

Soil moisture0~100%±3% (loam soils) High organic matter soils (soil organic carbon content > 12%) High clay content soils (clay content > 45%) Calibration may be required for specific soil types due to their dielectric relaxation properties0.1%---

Soil conductivity0~20000us/cm±3% (0~10000us/cm) ±5% (full range)1us/cm

3. Advantages and characteristics

★A single soil tube sensor can measure soil parameters at multiple depths simultaneously, and the monitoring depth can be customized (less than 1M).

★The sensor adopts low power design, with power consumption as low as 0.26W, suitable for long-term unmanned monitoring in the field.

★Each layer of the sensor can independently measure temperature, humidity, and conductivity parameters.

★The sensor shell is made of imported PC material, which is high in strength, corrosion-resistant and environmentally friendly.

★The sensor's waterproof rating reaches IP67, suitable for long-term outdoor monitoring.

★The sensor measures the average humidity in a certain area, making up for the limitations of single-point measurement.

★The sensor adopts a self-designed spiral measuring electrode to improve the contact between the sensor and the soil and minimize the measurement error caused by air gap.

4. Precautions for use

a. The sensor should be used strictly in accordance with the installation and operating instructions.

b. When multiple sensors work at the same time, they must be separated by a distance of more than 3 meters.

c. The sensor measurement principle is limited. There should be no electromagnetic cables and strong magnetic radiation interference within a radius of 3 meters from the sensor measurement site to avoid huge errors and damage to the sensor measurement.

d. The installation environment of the sensor should be consistent with the measurement range of the sensor to avoid irregularities such as over-range.

e. The sensor should be installed away from strong acid, strong alkali, heavy oil, heavy metal environment.

f. The sensor is a soil measurement sensor. It is prohibited to use this sensor to measure other substances.

g. The sensor installation environment must not have strong vibration.

h. The sensor cannot be subjected to excessive external force.

i. Disassembly is prohibited. Unauthorized disassembly is considered as non-compliant behavior and no service will be provided subsequently.

5. Installation method

Drilling method:

1. Take the drill bit, handle and support rod. After completion, place the drill vertically on the ground, hold the handle tightly with both hands and press down clockwise to rotate slowly. (Note: Do not use too much force, and be sure to rotate slowly for several circles to prevent the drill bit from deviating and causing the hole to be crooked)


Soil moisture monitoring station


2. Take the soil auger out of the hole, put it in a basin, and use tools to collect the soil drilled into the basin for mixing with mud. (Note: The first drilled soil is not collected because it has too many impurities)


Soil moisture monitoring station


3. Repeat the above drilling and soil extraction process, and try to gently place the sensor into the hole (do not force the device to touch the bottom) to test whether the depth of the hole is appropriate; if there is a jam, use the soil extraction drill to correct it to ensure that the sensor is smoothly inserted and removed; until the hole depth is flush with the installation position marked by the sensor (zero scale line), the drilling is completed.

4. Pick out the soil impurities, stones, roots, and insoluble soil clods in the pot. Rub the soil into a fine powder to make it easier to mix with mud.

5. Pour in an appropriate amount of water and stir thoroughly until it becomes viscous; loam mud should generally not be thicker than "sesame paste".


Soil moisture monitoring station


6. Slowly pour the mud into the hole, about 1/2 of the hole; the amount can be increased or decreased as appropriate based on actual conditions.


Soil moisture monitoring station


7. Slowly put the sensor into the hole, turn it clockwise and press it down. Too fast may cause the bubbles to not be completely discharged. (Note: Do not pull up the sensor during the turning and pressing process to prevent the gas from being sucked into the hole again)

8. When the sensor is installed to the correct depth, some mud will overflow around the device, and the grouting is completed; at this time, the sensor installation depth is flush with the hole. (Note: remove the excess mud outside 3CM around the sensor to prevent agglomeration from affecting water infiltration)

Burial method: Use a pickaxe to dig a deep pit for the sensor, and bury the sensor with mud. Refer to the drilling method for processing details.



Product address:http://m.25561.cn/en/turang/1121.html
Hello, my friend!
What kind of support do you need? Our products is sure to satisfy you.
*Name
*Email
Phone
Country
*Message
主站蜘蛛池模板: 久久精品免视看国产明星 | 国产精品久久香蕉免费播放 | 高h视频在线观看 | 国产精品成人久久久久久久 | 日本xxxx网站| 国产欧美一区二区三区久久 | 美女乱子bbw| 99久久综合狠狠综合久久男同 | 欧美日韩国产一区 | 亚洲国产综合精品中文第一区 | 免费国产黄网站在线观看 | 236宅片在线观看 | 亚洲αv | 9丨精品国产高清自在线看 aⅴ撸撸 | 色婷婷久久综合中文久久蜜桃 | 成人羞羞视频在线观看免费 | 日本乱人伦在线观看免费 | 日本在线不卡免费视频一区 | 台湾佬自偷自拍情侣在线 | 91中文字幕在线视频 | 天天爱天天操天天射 | 六月丁香深爱六月综合激情 | 国产成人一区二区三区影院免费 | 清纯唯美亚洲综合欧美色 | 欧美日韩国产另类一区二区三区 | 热久久视久久精品18国产 | 亚洲精品入口一区二区在线观看 | 国产一级持黄大片99久久 | 欧美日韩中文亚洲v在线综合 | 中文字幕欧美日韩 | 人人澡人人草 | 天天操天 | www视频免费在线观看 | 国产私密视频 | 99国产精品九九视频免费看 | 久久草精品| 久久国产精品一区二区三区 | 人人爱操 | 亚洲欧美日韩国产精品久久 | 欧美视频在线观看一区二区 | 久久涩精品 |